УЗИ сканер ClarUs
Доставка
Оплата
Характеристики
Опис
The ClarUs EXT-1M ultrasound system offers system flexibility and easy of use making it an excellent choice for any practice wanting a high quality color Doppler imaging system.
The system supports a wide range of linear, convex and microconvex transducers providing a platform that is versatile and offers great expansion potential as your practice needs grow.
The ClarUs EXT-1M provides uncompromising quality imaging along with precision measurement, storage, recall and convenient communication capability. Variable frequency and focusing, an extended cine memory and the ability to output your data in a variety of formats makes the ClarUs EXT-1M a powerful addition to any modern practice.
ClarUs EXT-1M Kit includes:
- ClarUs EXT-1M beamformer
- ultrasound transducer
- USB cable
- 100~240 VAC, 50~60 Hz power supply (EN60601-1)
- AC power cable
- software, assembly and set-up manual, operation manual (on USB memory)
Imaging Modes
- B
- B+B
- 4B
- B+M
- M
- B-steer (note)
- Compound + Trapezoid (note)
- Color Doppler (CFM)
- Power Doppler (PDI)
- Directional Power Doppler (DPDI)
- Pulsed Wave Doppler (PWD)
- B+PWD (Duplex)
- B+CFM/PDI/DPDI+PWD (Triplex)
- High Pulse Repetition Frequency (HPRF)
- Tissue Harmonic Imaging (THI), works with 3.5 MHz central frequency transducers
Note. 40mm and less linear probes only.
Ultrasound Imaging
- ultrasound image size: automatically adjustable to screen resolution
- gray scale: 256
- color scale: 256
- full motion and full size real-time ultrasound imaging, up to 120 fps (depends on selected scan depth, scan angle, focus mode, High Line Density setting, computer speed)
- cineloop recording/play: several thousands frames (depends on computer memory size and scan mode)
- zoom mode: from 60% to 600% in all modes (Scan, Freeze, B, B+B, 4B, Doppler modes, M-zoom, cineloop and etc)
- viewing area variable for frame rate maximizing: 6 steps
- thumbnail mode: up to 32 images
- "Freeze" mode
- "Auto Freeze" mode
Scanning Methods
- electronic linear
- electronic convex
- electronic microconvex
- scanning depth: 2-30 cm
Transducers
- from 2,0 MHz to 14,0 MHz
- multifrequency
- automatic transducer recognition
- number of ports: 1
Color Doppler
- PRF variable: 0.5-10 kHz
- wall filter settings: 3 steps (5%, 10%, 15% PRF)
- gain control: 50 dB
- angle steering for linear transducers: ±10°
- real-time spatial filter: 4 values
- CFM palette: 10 maps
- PDI palette: 12 maps
- B/Color priority control
- color threshold control
- CFM baseline control
- Doppler frequency selection: 2 frequencies / each transducer
- color frame averaging: 8 values
- Transparent Color Mapping (TCM): 10 values
Pulsed Wave Doppler
- PRF variable: 1-15 kHz
- wall filter settings: 16 steps (2.5-20% PRF)
- gain control: 50 dB
- angle steering for linear transducers: ±10°
- real-time trace line with automatic calculation of spectrum parameters
- stereo sound: volume control
- PWD palette: 12 maps
- Doppler frequency selection: 2 frequencies / each transducer
Focusing
- transmit: variable, 8 zones
- receive: dynamic, 8 zones
Automatic Image Optimization
- single click auto adjustment:
- B-image: gain, dynamic range, TGC sliders
- Color Doppler: CFM/PDI/DPDI gain
- Pulsed Waved Doppler: baseline, invert, PRF
Processings
- High Line Density scan mode for better resolution
- TGC Control, 5-10 sliders (customizable) 40 dB
- dynamic range: 120 dB, 8 values
- overall gain control
- M - mode sweep speed control
- acoustic power control
- variable frame averaging
- brightness, contrast
- advanced gamma control: 8 fixed curves, 8 user defined (custom)
- scan direction, rotation, up-down controls
- negative / positive control
- bi-linear interpolation
- echo enhancement control
- noise rejection function
- speckle reduction and structure improvement PureView, NeatView, QuickView: 8 algorithms each
DICOM
- Verification SCU
- Modality Worklist (MWL) SCU
- Modality Performed Procedure Step (MPPS) SCU
- Store SCU (images, cines)
- Print SCU (grayscale, color)
For more information see Echo Wave II Software DICOM Conformance Statement
Functions
- mouse / trackball / keyboard operation
- image and video save / load:
- AVI
- JPG
- BMP
- PNG
- TIF
- XLSX
- DCM (DICOM uncompressed)
- DCM (DICOM-JPEG RGB/YBR)
- DCM (DICOM-JPEG RGB/YBR Video)
- TPD (Telemed Picture Data)
- TVD (Telemed Video Data)
- unlimited programmable presets for clinically specific imaging
- anatomical icons with transducer position indicator
- direct e-mail sending with image or video attachment via Internet
- DICOM file push to server
- printing on system printer
- TV output via computer display adapter
- multi-monitor support
- full screen and window mode
- LB-2 keyboard (optional) support
Interface Customization
- the set of predefined skin schemes for software interface
- the set of predefined buttons images
- multilanguage support, languages:
- Chinese
- English
- French
- German
- Italian
- Korean
- Lithuanian
- Magyar
- Polish
- Romanian
- Russian
- Spanish
- B+M, B+PW layout position, size
- ultrasound area size
- font size
General Measurements and Calculations
- B and Color Doppler mode general measurements and calculations
- Distance
- Length (method: 1 trace)
- Area, Circumference (methods: 1 ellipse, 1 trace, 1 distance)
- Volume (methods: 1 distance, 2 distances, 3 distances, 1 ellipse)
- Angle (methods: 2 distances, 3 distances)
- Stenosis % (methods: 2 distances, 2 ellipse or trace areas)
- A/B Ratio (methods: 2 distances, 2 ellipse or trace areas, 2 ellipse or trace circumferences)
- M mode general measurements and calculations
- Distance, Time, Velocity
- Heart Rate (methods: 1 beat, 2 beats)
- Stenosis % (method: 2 distances)
- A/B Ratio (methods: 2 distances, 2 times, 2 velocities)
- PW mode general measurements and calculations
- One-point PW measurements and calculations:
- Velocity
- Pressure Gradient (PG)
PW mode Human Cardiology measurements and calculations
- Left Ventricle: LVOT Diam, LVOT VTI, LVOT Vmax, SV (Stroke Volume), SI (Stroke Volume Index), CO (Cardiac Output), CI (Cardiac Index), dP:dt (Delta Pressure : Delta Time), MPI (Left Ventricle Myocardial Performance Index)
- Mitral Valve: MVA(PHT) (Mitral Valve Area using Pressure Half Time), MVA using Continuity Equation (LVOT Diam, MV VTI; LVOT Diam, MV Vmax), dP:dt, E/A ratio
- Aortic Valve: AVA (Aortic Valve Area) using Continuity Equation (LVOT Diam, AV VTI; LVOT Diam, AV Vmax), AVI (Aortic Valve Index), DPI (Dimensionless Performance Index), AV PHT (Aortic Valve Pressure Half Time)
- Right Ventricle: RVOT Diam, RVOT VTI, RVOT Vmax, dP:dt, RV MPI (Right Ventricle Myocardial Performance Index), MPAP (Mean Pulmonary Artery Pressure)
- Tricuspid Valve: TVA (Tricuspid Valve Area) using Continuity Equation (RVOT Diam, TV VTI; RVOT Diam, TV Vmax); TV E/A ratio, TV PHT
- Pulmonic Valve: PVA (Pulmonic Valve Area) using Continuity Equation (RVOT Diam, PV VTI; RVOT Diam, PV Vmax), PVI (Pulmonic Valve Index), DPI (Dimensionless Performance Index), PV PHT (Pulmonic Valve Pressure Half Time)
- Pulmonary Vein; Hepatic Vein
- Shunts: Qp:Qs (Pulmonary-Systemic Flow Ratio)
Human Measurements and Calculations Packages
- Human General
- Measurements: the same as general measurements of different modes (B, M, PW)
- Calculations: BSA via Height and Weight, BSA via Weight
- PW mode calculations: HR, SV using Flow Area, SV using Flow Diameter, SI, CO, CI, Area calculation using Continuity Equation (methods: Area and VTI, Area and Velocity, Diameter and VTI, Diameter and Velocity, Velocity Ratio (S/D, D/S), dP:dt, Flow Volume (methods: Diameter, Area), PHT, MVA
- Human Musculoskeletal
- Hip Angles (α, β), Femoral Head Coverage (FHC)
- Human Obstetrics / Gynecology (OB / GYN)
- Measurements: LMP (entered or from calendar), AC, BPD, FL, HC, FTA, AAPD, ATD, TAPD, TTD, CRL, GS, HL, TL, UL, OFD, BOD, Cereb, Clav, Rad, AFI, FHR, NT
- Doppler mode measurements: Umbilical Artery (UA): RI, PI, PSV, EDV; Middle Cerebral Artery (MCA): RI, PI, PSV; Ductus Arteriosus (DA): Diam, PSV; Main Pulmonary Artery (MPA): Diam, PSV; Uterine Artery (UtA): RI, PI
- Doppler mode calculations: Umbilical Artery (UA): PSV/EDV; CPR
- Estimated date of birth (EDD) calculations: EDD(LMP), EDD(GA), EDD(AUA)
- Ratios: FL / AC, FL / HC, FL / BPD, HC / AC, CI
Veterinary Calculations Packages
- Canine OB
- Measurements: GS, CRL, HD, BD
- Gestational Age (GA) calculations: GA(BD), GA(CRL), GA(GS), GA(HD)
- Feline OB
- Measurements: HD, BD
- Gestational Age (GA) calculations: GA(BD), GA(HD)
- Ovine OB
- Measurements: CRL
- Gestational Age (GA) calculations: GA(CRL)
- Bovine OB
- Measurements: BD, CRL, HD, UD
- Gestational Age (GA) calculations: GA(BD), GA(CRL), GA(HD), GA(UD)
Power
ClarUs:
- integrated power supply, 100~240V AC, 50~60 Hz
- battery powered:
- battery type: Li-Ion technology
- battery life: 90 min (actual battery life will vary depending on scan mode)
- battery charging time: 2 hours
ClarUs EXT-1M:
- external power supply, 100~240V AC, 50~60 Hz
Dimensions, Weight
- dimensions W x D x H, mm:
- ClarUs EXT-1M: 46 x 202 x 165
- weight, kg:
- ClarUs EXT-1M, 1.4
Ultrasound software
- TELEMED Drivers Package (32/64-bit Windows®)
- Echo Wave II software (32/64-bit Windows®)
- 3DView plug-in (optional, 32-bit Windows® only)
- PanoView plug-in (optional, 32-bit Windows® only)
- SDK documentation / sample code (available by agreement)
- Echo Wave II start-up time: 30 sec (Core 2 Duo 2.66 GHz, 2 Gb of RAM)
Recommended Computer Requirements
- Windows® based Desktop/Notebook/Tablet PC
- Screen 1024x768 or more, IPS or PLS technology
- CPU i3/i5/i7 1.8 GHz or faster
- 2 Gb of RAM or more
- USB 2.0 interface
- Windows® XP SP3, Windows® Vista SP2, Windows® 7, Windows® 8, Windows® 10 (all versions 32/64-bit)
Probes
MCV9-5R10N-3 | MC10-5R10N-3 | MC10-4R12N-4 |
MC5-2R20N-3 | MC10-5R20NI-3 | C7-3R50NI-5 |
C5-2R60NI-5 | L15-6L25N-4 | L12-5L40N-4 |
LV8-5L60N-2 veterinary |